Wire-In Light Control with Swivel Mount

Wire-In Light Control with Swivel Mount

Regular price $0.00 $0.00
Shipping calculated at checkout.
- +

Share this Product

Swivel Mount Allows Easy Adjustment For Photo Eye Look-Out Direction
Works With CFL, Incandescents, Mercury Vapor, Metal Halide, Sodium Vapor, LED, Halogen And Fluorescent Bulbs
Discourages Intruders By Automatically Lighting Grounds At Night Time
Stylish & Rugged Design, UL Tested for Minimum 6,000 Cycles (16.4 Years Daily On/Off) At 15Amp 1800W Tungsten & 1000VA Ballast Loads

Features

  • Swivel Base Easily Adjusts to Look-Out Direction
  • Excellent Replacement PhotoControl For Twin Floodlights, Area Lights, Walkway Lighting & Building Perimeter Lights
  • Works With CFL, Incandescents, Mercury Vapor, Metal Halide, Sodium Vapor, LED, Halogen and Fluorescent Bulbs
  • Discourages Intruders By Automatically Lighting Grounds At Night
  • Saves Energy, Bulb Life, Electricity & Money By Automatically Reducing Daily Operating Time
  • Activates With Natural Sunlight, No Adjustment Needed For Daylight Savings Time
  • Built-In Time Delay Eliminates False On/Off Due To Lightning And Stray Car Lights
  • UL Tested for Minimum 6,000 Cycles (16.4 Years of Daily On/Off) at Maximum Possible Rated Electrical Loads
  • Heavy Duty Capacity: Max. 15Amp 1800W Tungsten, 1000VA Ballast 120VAC 50/60 Hz

Technical Specifications

  • Extra Large Capacity: 15Amp 1800W Tungsten, 1000VA Ballast 120VAC 50/60 Hz
  • Works With Incandescent, CFL, Mercury Vapor, Metal Halide, Sodium Vapor, Halogen, LED and Fluorescent Bulbs
  • Swivel Base Easily Adjusts to Look-Out Direction
  • Automatically ON at 1 +/-0.5 Foot Candle & OFF at 6 +/-0.5 Foot Candles
  • UL Tested for Minimum 6,000 Cycles (16.4 Years Daily On/Off) At Minimum 15Amp 1800W Tungsten & 1000VA Ballast Loads
  • Unit Provided With Color Coded 6"Long Lead Wires
  • Extra Safety 16AWG 600V Lead Wires UL Rated For Higher Temperature of 150C
  • For Correct Operations & To Avoid Permanent Equipment Damage, Installer Must Connect All 3-Wires Exactly As Diagram Shows On The Unit
  • Built-In Safety Time Delay: 20 to 100 Seconds
  • Rugged Outdoor Operating Temperature Range: -40F to +158F (or -40C to +70C)
  • Excellent On/Off Ratio: 6
  • Low Average Power Consumption: 0.8W
  • Must Install Unit Using UL Listed Outdoor Junction Box or Raintight Fixture
  • UL Listed for USA/Canada Under Our File No. E322033
  • Meets UL Standard 773A & Canadian C22.2 No. 205-M1983

 

Installation Instructions:

 

Use With Weatherproof  Light Fixture Enclosures 

Read All Instructions Completely Before Beginning Installation.

CAUTION: TO PREVENT INJURY FROM ELECTRICAL SHOCK AND POSSIBLE RISK OF DEATH, POWER MUST BE TURNED OFF AT THE MAIN CIRCUIT BREAKER OR AT THE MAIN FUSE BOX BEFORE INSTALLING PHOTOCONTROL.

 

Use only U. L. Listed wire connectors (not included). All metal strands of wires MUST be completely inside wire connectors. Wrap electrical tape in multiple layers to further secure the connections.

  1. Connect the red wire from the Photo Control to the black wire of the light fixture.
  2. Connect black wire from the Photo Control to the black (hot power supply) wire.
  3. Connect all of the white wires (neutral) together.
  4. The body of control must be screwed to weatherproof electrical enclosure. Make sure photocell is directed towards natural sunlight and away from any reflected or artificial light. Screw the silver color die-cast metallic nut with black gasket tight enough to make a weatherproof seal. If the surface is uneven, apply RTV silicone rubber outdoor sealing compound before installing photocontrol.
  5. Turn power on. Photo Eye has up to 2-minutes delay when turning the power On/Off.

Troubleshooting Guide:

1. If lamp cycles On/Off during the day, check that photo control black and red wire connections are not reversed.

2. If lamp cycles during night then somehow reflected light is falling on photocell. Change look-out direction of photocell towards natural sunlight. If not possible then use black electrical tape to partially obstruct the sensor to limit reflected light from entering the photocell.

3. If lamp does not turn On during night time then red and black wires of photo control are connected wrong. In this case photocontrol is DESTROYED due to wrong wiring connections and MUST NOT be returned back.

4. If photo control was ever connected to 208V or higher voltage, it cannot be used for 120V application anymore.

5. Photo control will not work with 12V/24V low voltage landscape lights.

 

Note: For any question, please contact us at      Service@touchandglow.com


Net Orders Checkout

Item Price Qty Total
Subtotal $0.00
Shipping
Total

Shipping Address

Shipping Methods